PIERCE HUMAN IL-2 ELISA KIT96 assays
 |
|
包装: |
96 assays |
运保温度: |
|
到货周期: |
登录后查看 |
标准价: |
¥客户可见 |
会员价: |
¥客户可见 |
积分: |
客户可见 分 |
|
|
运费与支付说明:
1.含干冰类产品有运费;
2. 必须现金付款或有信用额度的会员才可以直接发货,否则需要等待现金付款信息。 |
|
其它组分:
Anti-Human IL-2 Precoated 96-well Strip Plate, 1 each
Lyophilized Recombinant Human IL-2 Standard, 2 vials
Standard Diluent, 14mL
Biotinylated Antibody Reagent, 8mL
30X Wash Buffer, 50mL
Streptavidin-HRP Concentrate, 75μL
HRP Dilution Buffer, 14mL
TMB Substrate Solution, 13mL
Stop Solution, 13mL
Adhesive Plate Covers, 6 each
描述:
Assay IL-2 (human interleukin-2) levels in human serum, plasma (EDTA, heparin, sodium citrate), urine and culture supernatant samples with our Thermo Scientific Human IL-2 ELISA Kits.
These human IL-2 ELISA kits use pre-titered, matched pairs of coating and detection antibodies to achieve sensitive and accurate measurement of interleukin-2 (IL-2) in samples at 50 to 100μL per well. Also included are calibrated recombinant protein standard, streptavidin-HRP, TMB substrate solution and stop solution. The complete kits contain pre-coated 96-well strip plate(s) and lot-optimized reagents. The economically-priced reagent kit provides validated reagents only, requiring users to coat their own plates. The antibody-pair kit consists of the matched IL-2 antibody pairs and IL-2 standard only. All components undergo quality control testing to minimize lot-to-lot variability.
Highlights: †
• Target: natural and recombinant human interleukin-2 (IL-2)
• Format: colorimetric ELISA (TMB substrate) in clear 96-well strip plate
• Measurement: absorbance at 450nm minus absorbance at 550nm
• Assay Range: 38.4 to 1500pg/mL
• Sensitivity: < 6pg/mL
• Precision: intra-assay CV < 10%; inter-assay CV < 10%
• Sample Types: cell culture supernatant, serum, plasma (EDTA, sodium citrate and heparin)
• Total Assay Time: 4 hours
• Sample Size: 50μL
• Specificity: no significant cross-reaction with human IL-1α, IL-1β, IL-3, IL-4, IL-6, IL-7, IL-8, TNFα, TNFβ, GM-CSF, INFγ, or mouse IL-2.
† Note: Assay range and other values listed above are for the pre-coated plate kit; see product documentation for values specific to the reagent kit and antibody-pair kit.
Includes:
Complete Kits contain pre-coated antibody-plates, detection antibodies, buffers, diluents, standards, and substrates. The Reagent Kit (previously called a "Screening Set") contains matched antibodies, standard and detection reagents but no coated plates. The Antibody Pair Kit (previously called a "MiniKit") contains only matched antibodies and standard (no plates or detection reagents).
Details:
 |
Human IL-2 ELISA standard curve. An example standard curve for the Thermo Scientific Human IL-2 ELISA Kit (Part No. EH2IL2), with error bars based on five replicates for each interleukin-2 standard concentration. Also see standard curves for the IL-2 Reagent Kit and IL-2 Antibody Pair Kit. |
原厂资料:
Assay IL-2 (human interleukin-2) levels in human serum, plasma (EDTA, heparin, sodium citrate), urine and culture supernatant samples with our Thermo Scientific Human IL-2 ELISA Kits.
These human IL-2 ELISA kits use pre-titered, matched pairs of coating and detection antibodies to achieve sensitive and accurate measurement of interleukin-2 (IL-2) in samples at 50 to 100μL per well. Also included are calibrated recombinant protein standard, streptavidin-HRP, TMB substrate solution and stop solution. The complete kits contain pre-coated 96-well strip plate(s) and lot-optimized reagents. The economically-priced reagent kit provides validated reagents only, requiring users to coat their own plates. The antibody-pair kit consists of the matched IL-2 antibody pairs and IL-2 standard only. All components undergo quality control testing to minimize lot-to-lot variability.
Highlights: †
• Target: natural and recombinant human interleukin-2 (IL-2)
• Format: colorimetric ELISA (TMB substrate) in clear 96-well strip plate
• Measurement: absorbance at 450nm minus absorbance at 550nm
• Assay Range: 38.4 to 1500pg/mL
• Sensitivity: < 6pg/mL
• Precision: intra-assay CV < 10%; inter-assay CV < 10%
• Sample Types: cell culture supernatant, serum, plasma (EDTA, sodium citrate and heparin)
• Total Assay Time: 4 hours
• Sample Size: 50μL
• Specificity: no significant cross-reaction with human IL-1α, IL-1β, IL-3, IL-4, IL-6, IL-7, IL-8, TNFα, TNFβ, GM-CSF, INFγ, or mouse IL-2.
† Note: Assay range and other values listed above are for the pre-coated plate kit; see product documentation for values specific to the reagent kit and antibody-pair kit.
Includes:
Complete Kits contain pre-coated antibody-plates, detection antibodies, buffers, diluents, standards, and substrates. The Reagent Kit (previously called a "Screening Set") contains matched antibodies, standard and detection reagents but no coated plates. The Antibody Pair Kit (previously called a "MiniKit") contains only matched antibodies and standard (no plates or detection reagents).
Details:
 |
Human IL-2 ELISA standard curve. An example standard curve for the Thermo Scientific Human IL-2 ELISA Kit (Part No. EH2IL2), with error bars based on five replicates for each interleukin-2 standard concentration. Also see standard curves for the IL-2 Reagent Kit and IL-2 Antibody Pair Kit. |