收藏本站
热门搜索: A3500  E1910  A1360  25200056  dmem  

Verso 1-Step RT-PCR Kit with ReddyMix buffer

 
包装: 200 x 50 μl rxns
运保温度: -20℃
到货周期: 登录后查看
标准价: ¥客户可见
会员价: ¥客户可见
积分: 客户可见
 
登录之后可加入购物车购买,请您 
对比 收藏

运费与支付说明:

1.含干冰类产品有运费;

2. 必须现金付款或有信用额度的会员才可以直接发货,否则需要等待现金付款信息。

描述:

Thermo Scientific Verso 1-Step RT-PCR system is a complete set of RT-PCR reagents that combines everything needed for RT-PCR. The Verso RT enzyme delivers high processivity and can be used at temperatures up to 57°C, delivering effective transcription through difficult RNA secondary structures. Verso also shows a better dynamic range than standard AMV or M-MuLV enzymes, with increases in template concentration giving rise to corresponding increases in product generated over a wider range of starting material concentrations.

The Verso system is available with ThermoPrime (standard PCR) or Thermo-Start (hot start) polymerase, the latter providing a more specific option that delivers higher yields and greatly reduces nonspecific primer extension before PCR. Thermo-Start Taq DNA Polymerase is a chemically-modified polymerase that remains inactive throughout the RT step, activated only by the high-temperature incubation (95°C for 15 minutes) prior to PCR.

An optional RT Enhancer is provided with kits and can be used during the RT step to remove any DNA contamination, eliminating the need for DNase I treatment.

The Verso 1-step RT-PCR system is also available with a ReddyMix option, where the master mix contains a dye and precipitant that allow RT-PCR reactions to be loaded directly onto an electrophoresis gel. The red dye migrates between bromophenol blue and xylene cyanol at approximately 300 bp, depending on agarose concentration.

 

Highlights

  • Eliminate the need for DNase treatments – RT Enhancer (optional) prevents gDNA carry-over
  • Enzyme choice – Standard PCR or hot start options available
  • Available as ReddyMix formulation – eliminate post-PCR steps required for electrophoresis
  • RT and PCR steps performed in single sealed tube – convenience and reduced contamination risk
  • Verso enzyme is highly sensitive in a broad dynamic range – accurately detect RNA input from 1 pg to 1 μg
  • Wide working temperature range (42 to57°C) for success with GC-rich and other difficult templates
  • RNase Inhibitor included in RT enzyme mix

 

Applications

  • Gene expression analysis
  • Viral/bacterial detection
  • 1-step RT-PCR
  • High throughput applications

 

Includes

  • Verso Enzyme Mix (includes RNase inhibitor)
  • 2X Master Mix (ThermoPrime Taq DNA Polymerase, RT buffer, dNTPs, MgCl2 in ReddyMix formulation)
  • RT Enhancer


相关图片

本产品可用于的实验

购此产品的人还购买了
最近浏览产品

京ICP备15036693号-2    京公网安备11010802025653    版权所有:北京逸优科技有限公司       0.04

 纠 错