收藏本站
热门搜索: A3500  E1910  A1360  25200056  dmem  

AMPLEX RED GLUTAMIC AC 1 KIT

 
包装:
运保温度: -5 to -30°C)
到货周期: 登录后查看
标准价: ¥客户可见
会员价: ¥客户可见
积分: 客户可见
 
登录之后可加入购物车购买,请您 
对比 收藏

运费与支付说明:

1.含干冰类产品有运费;

2. 必须现金付款或有信用额度的会员才可以直接发货,否则需要等待现金付款信息。

描述:

The Amplex® Red Glutamic Acid/Glutamate Oxidase Assay Kit provides a sensitive and simple method for detecting glutamic acid/glutamate oxidase activity using a fluorescence microplate reader or fluorometer.

See our complete line of Fluorescence Microplate assays.

• Detect concentrations as low as 10 nM L-glutamic acid or 40 µU/mL of purified L-glutamate oxidase
• Format allows for multiple time point measurements
• Designed for minimal autofluorescence interference

The Amplex® Red Glutamic Acid/Glutamate Oxidase Assay Kit provides an ultrasensitive method for detecting glutamic acid or for continuously monitoring glutamate oxidase activity using a fluorescence microplate reader or fluorometer. In the assay, L-glutamic acid is oxidized by glutamate oxidase to produce α-ketoglutarate, NH3, and hydrogen peroxide. L-alanine and L-glutamate–pyruvate transaminase are included in the reaction to regenerate L-glutamic acid by transamination of α-ketoglutarate, resulting in multiple cycles of the initial reaction and a significant amplification of the hydrogen peroxide produced. The hydrogen peroxide reacts with 10-acetyl-3,7-dihydroxyphenoxazine (Amplex® Red reagent) in a 1:1 stoichiometric ratio in a reaction catalyzed by horseradish peroxidase (HRP) to generate the highly fluorescent product resorufin.

Because resorufin has absorption and fluorescence emission maxima of approximately 571 nm and 585 nm, respectively, there is little interference from autofluorescence in most biological samples.

Use Amplex® Red Assays for a Broad Range of Investigations
A wide variety of validated Amplex® Red assays are available for studying cell signaling and lipids, neurobiology, inflammation and immune function, and metabolism. We also offer Amplex® UltraRed Reagent (Cat. No. A36006), a second-generation reagent providing greater sensitivity and brighter fluorescence, and the Amplex® Red/UltraRed Stop Reagent (Cat. No. A33855). The Amplex® Red/UltraRed Stop Reagent provides convenience and control by allowing the fluorescence signal-generating reaction to be terminated at a user-determined time point. After addition of the stop reagent, the fluorescence signal remains stable for at least three hours. Custom assay design and packaging are also available.


注意事项:

For Research Use Only. Not for use in diagnostic procedures.


相关图片

本产品可用于的实验

购此产品的人还购买了
最近浏览产品

京ICP备15036693号-2    京公网安备11010802025653    版权所有:北京逸优科技有限公司       0.04

 纠 错